Multidrive 1PH Thyristor Power Controller

Multidrive 1PH Thyristor Power Controller

  • Thyristors suitable for resistive, inductive & transformer loads
  • Current range – 850A, 1000A, 1400A, 1500A, 1850A, 2000A, 2400A, 2700A
  • Supply voltage up to 480V as standard, 600V & 690V available as option
  • Microprocessor based electronic circuit fully isolated from the power
  • Firing types include Burst Firing (BF), Single Cycle (SC), Soft Start + Burst Firing (S+BF), Delayed Triggering + Burst Firing
  • (DT+BF), Phase Angle (PA), Soft Start + Phase Angle (S+PA).
  • Input signals from 4-20mA, 0-10V DC Linear input, 10K Pot or RS485 comms
  • Selectable control modes include V, I, VxI, V2
  • Current limit as standard including internal current transformer, fully adjustable via front panel keypad
  • Profiling of current limit via analogue input
  • Heater Break (HB) alarm to diagnose partial or total load failure with automatic setting, relay alarm output and front LED indication.
  • 4 configurable Analogue outputs, 4 Relay outputs and 6 Digital inputs as standard
  • Internal quick-blow fuses as standard
  • RS485 comms (Modbus Protocol) as standard
  • Critical Alarms monitor phase loss, rotation and provide Thermal Protection
  • Special design Heatsink with high dissipation value
  • IP20 protectionComplies with CE specification.

Thyristor Configurator V5.3.0.7- CD3000 series - MULTUDRIVE (17,1 MB, 298 downloads)

Related Products

TU-RS485-ETH-DL-IO Ethernet to Modbus Converter
TU-RS485-ETH-DL-IO Ethernet to Modbus Converter
  • N.1 serial interface RS-485 Modbus RTU Master
  • N.1 serial interface RS-485/232 Modbus RTU Slave
  • USB Port with USB 8GB Memory Key for Data Logging
  • Interface Ethernet 10Base-T, Modbus TCP
  • N.4 Digital Inputs + N.2 SPDT Relays
  • Functional Block programming software
TU-RS485-PB Profibus DP to Modbus RTU Converter
TU-RS485-PB Profibus DP to Modbus RTU Converter
  • Protocol Converter / Gateway from serial interface to PROFIBUS DP
  • The PROTOCOL CONVERTER TU-RS485-PB connects devices such as thyristor units, controller and soft starter via their serial interfaces to Profibus DP. RS232, RS485 und RS422 interfaces are on Board as a standard feature.
REVO KP2
REVO KP2
  • Up to 6 zone can be managed
  • 4.3, 7.0, 10” Colour Display
  • Trend display
  • Thyristor Configuration Recipy Management
  • Multi Language Interface
  • For REVO M, REVO CL, CD3000E and MULTIDRIVE.
CD KP Operating terminals for Thyristor Units
CD KP Operating terminals for Thyristor Units
  • Operating terminals for Thyristor Units
  • N°2 Display
  • 48x96 Front Panel
  • Re-Transmission
  • Thyristor Configuration Port
  • Multi Language Interface
  • For CD3000M, CD3200, CD3000E and MULTIDRIVE.